DC Machines & Transformer

Parallel Operation of Two 1-ph Transformers to Determine the Sharing of Load Current, Apparent and Real Power

Experiment No.: 6(B) Experiment Name: Parallel Operation of Two 1-ph Transformers to Determine the Sharing of Load Current, Apparent and Real Power. Objective: To perform parallel operation of two 1-ph transformers To determine the sharing of load current, apparent power and real power Theory: Parallel operation of transformers is used for load sharing. The transformers […]

Parallel Operation of Two 1-ph Transformers to Determine the Sharing of Load Current, Apparent and Real Power Read More »

Polarity Test for Operation of Two Single Phase Transformers in Parallel

Experiment No.: 6(A) Experiment Name: Polarity Test for Operation of Two Single Phase Transformers in Parallel. Objective: To test polarity of two single phase transformers. Theory: We do polarity test on parallel transformers to ensure that we connect the same polarity windings and not the opposite ones. If we accidentally connect the opposite polarities of

Polarity Test for Operation of Two Single Phase Transformers in Parallel Read More »

Regulation & Efficiency Test of Single-phase Transformer by Direct Loading Method

Experiment No.: 5 Experiment Name: Determine the regulation & efficiency of single-phase transformer by direct loading method. Objective: To determine Regulation of single-phase transformer by direct loading method Efficiency of single-phase transformer by direct loading method Theory: Although two chief difficulties which do not warrant the testing of large transformer by direct load test are:

Regulation & Efficiency Test of Single-phase Transformer by Direct Loading Method Read More »

Short Circuit Test of Single Phase Transformer

Experiment No.: 4(B) Experiment Name: Determination of equivalent circuit parameters of single-phase transformer by performing Short Circuit test Objective: The objective of the experiment is to find out Copper loss at any load Different parameters of the transformer with respect to high voltage side & low voltage side (i.e. equivalent resistance, equivalent impedance etc.), with

Short Circuit Test of Single Phase Transformer Read More »

Open Circuit Test of Single Phase Transformer

Experiment No.: 4(A) Experiment Name: Determine Equivalent Circuit Parameters of Single-Phase Transformer by Performing O.C. Test Objective: To perform the O.C. test of a single- phase transformer with the help of an ammeter, voltmeter and a wattmeter and to find out the core loss of the transformer, different parameter at no load condition and to predetermine the

Open Circuit Test of Single Phase Transformer Read More »

Control the Speed of DC Shunt Motor BELOW Rated Speed & Draw the Speed Characteristics

Experiment No.: 3(B) Experiment Name: Control the Speed of DC Shunt Motor Below Rated Speed & Draw the Speed Characteristics. Objective: Theory: A resistance is necessary to connect in series of the armature to control initial high starting current because armature has low resistance. When motor armature rotates, the armature conductor also rotate and hence

Control the Speed of DC Shunt Motor BELOW Rated Speed & Draw the Speed Characteristics Read More »

Control the Speed of DC Shunt Motor ABOVE Rated Speed & Draw the Speed Characteristics

Experiment No.: 3(A) Experiment Name: Control the Speed of DC Shunt Motor Above Rated Speed & Draw the Speed Characteristics. Objective: To control the speed of a DC Shunt Motor by field control method. To draw the field current vs. speed characteristics. Theory: The flux of a DC motor can be changed by changing the

Control the Speed of DC Shunt Motor ABOVE Rated Speed & Draw the Speed Characteristics Read More »

Plot the O.C.C. of a D. C. Generator & find the Critical Resistance

Experiment No.: 1 Experiment Name: Plot the O.C.C. of a D. C. Generator & find the Critical Resistance. Objective: To plot open circuit characteristics of a DC shunt generator To find critical resistance from the characteristics curve Theory: In a DC Generator an expression for the voltage generated (E) in the armature winding can be

Plot the O.C.C. of a D. C. Generator & find the Critical Resistance Read More »

Free Mock Test Series on SSC JE Electrical. Test yourself Now!

X

You cannot copy content of this page

error